Sarnafil T Chem. / Techn. Products
Sarnafil
T Prep
Material and Use If
Sarnafil T is not to be welded using the Sarnamatic with Prep nozzle, the contact surfaces of seams
must be prime-washed with Sarnafil T Prep before welding. Sarnafil T Prep is also used as a general-purpose
cleaner to remove surface dirt from Sarnafil T membrane during installation and to remove bitumen residue
from the membrane. Sarnafil T Clean should be used to remove “old” dirt stains from Sarnafil T surfaces.

Application
Recommendations The seam
areas of Sarnafil T membrane to be welded should be washed with a clean cloth saturated with Sarnafil
T Prep. The chemical must be allowed to evaporate before welding the membrane. Use a
solvent-resistant cloth only. We recommend using the Sarnafil Seam Preparation Set or WetTask Set. For
more information refer to the EU Safety Data Sheet for
this product.
Sarnafil
T Clean
Material and Use Sarnafil
T Clean is used for cleaning heavily stained Sarnafil T surfaces.

Application
Recommendations Depending
on the degree of soiling, the stain should first be cleaned with water, etc. Then saturate a clean,
solvent-resistant cloth with Sarnafil T Clean. Wipe clean the membrane surfaces to be welded. Let chemical
evaporate. Sarnafil T Clean should be used for cleaning heavily soiled membrane only. Before welding
the Sarnafil T membrane, the seam areas must be prime-washed with Sarnafil T Prep. For
more information refer to the EU Safety Data Sheet for
this
product.
Seam
Preparation Set The Seam
Preparation Set makes seam preparation and cleaning easy. The set includes 150 white solvent-resistant
fleece cloths and 100 disposable PE gloves. When cleaning seams, the
cloths should be periodically replaced, otherwise dirt will be spread instead of removed. A different
cloth should be used for prime-washing the seams. Cloths moistened with Sarnafil T Clean
may not be used for prime-washing seams.

WetTask-Set The
WetTask Set consists of a dispenser bucket, a large roll of 300 solvent-resistant white
cloths, and 100 disposable PE gloves.
Remove the gloves from the container.
Fill container with 5 litres of Sarnafil T Prep and fasten lid tightly. Pull each cloth through the
dispenser opening. The cloths are ready to use, pre-saturated with Sarnafil T Prep, making seam preparation
an efficient task.
To reduce evaporation of the solvent, close the dispenser
cap after each use. The fleece roll can be reloaded with Sarnafil T Prep as needed. To avoid unintentional
mixing, always fill the WetTask Set with Sarnafil T Prep only.
The dispenser
bucket is reusable. A refill set is available that includes a large cloth roll and disposable PE gloves.
© 2004 Sarnafil International AG Legal Disclaimer
|
|